Orthoralix 8500

Features

  • Multi-motorized rotation with up to 3 computer controlled motors offers the best diagnostic image quality with constant magnification factor
  • High frequency DC X-ray source with a 0.4mm focal spot for ultimate diagnostic results
  • One touch pad manages system movements and the other controls technique factors
  • Three laser beams enable precise patient positioning
  • Lateral positioning devices, handgrip and integrated chin rest allow patient to be held in a stable and comfortable position
  • Telescopic column and optional light, free standing base provide easy installation




Better Imaging

Multi-motorized rotation
The Orthoralix 8500 provides the best imaging performance possible through multi-motorized rotation. The rotating arm has freedom of motion with each movement driven be a separated, microprocessor-controlled motor. Until recently, only higher-priced panoramic systems offered this benefit.

  • The X-ray tube is completely free to rotate and relocate itself forward and backward, right and left
  • Free movements of the X-ray tubehead allows the best focal trough reconstruction
  • The pan unit accurately follows the patient's morphology to assure the best focal trough in terms of shape and thickness




Highest detail recognition

Projections-standard and child panoramic
  • High frequency DC X-ray generator
  • Smallest focal spot (0.4mm) for the sharpest image quality
  • kV modulation for the best reconstruction of images
  • Wide possibility for technical factors settings, both preset and manual
  • Specific trajectory of overhead movement guarantees a precise adaptation to a child's morphology




Easy patient positioning

On-board user interface for efficient workflow and easy patient positioning

  • One touch pad manages system movements while the other is used for technical settings
  • A 3-laser positioning system allows an easy setting of the mid-sagittal plane, the Frankfurt plane and the image layer
  • The patient is held in a stable and comfortable position through the lateral positioning devices, bite block, chin rest, and spring supports.




Easy integration

Advanced and ergonomic design
  • The telescopic column is the most significant element
  • Minimum space occupation and simplification of cleaning and disinfections
  • compact and appealing design




Technical Data

Description Value
Power supply 120 VAC ± 10% , 230 VAC ± 10%
Frequency 50/60 Hz ± 2 Hz
Max line power rating 10A @ 250V-15A@115V
Anode voltage 60-80 kV
Anode current 4-10 mA
Exposure time 11 s for child pan, 12 s for standard pan
Focal spot 0.4 - IEC 60336 (1993)
Panoramic cassette Flat 15 X 30 cm (6"X12")
Weight 115kg (254 lbs)




Newsletter

 
Gendex Dental Systems
901 West Oakton Street
Des Plaines, IL 60018

Phone: 1-800-323-8029
Fax: 847-550-1322
Tech Dept Fax: 847-718-0716
info@gendex.com